Case studies and testimonials
YESfloc® COEX88 – Biological treatment of industrial WW
Other

YESfloc® COEX88 – Biological treatment of industrial WW

Sludge Dewatering Equipment: VOLUTE™ Dewatering Press

Operational issues: complicated sludge, instable sludge quality (pH, SS), use of two types of polymer (coagulant and flocculant)

Polymer type Sludge Concentration

%

Sludge Volume

l/hr

Polymer dosage kg/SS/hr Dryness

%

Dewatered sludge volume

kg/hr

Coagulant + flocculant 2,13 150 3,5 + 0,7 15 21,3
YESfloc COEX88 0,08 19 16,8
  • Replaced two products by one
  • Improved storage and operation
  • Reduced total polymer dosage by 88%